PowerPanel™ Business Edition
40
The settings of UPS is faulty event would be applied with the settings of the Battery capacity is critically low event.
Event List
The Event List displays power events. The events displayed vary depending on whether they are listed in
Agent or Client and which UPS/PDU is providing the events.
z Battery capacity is critically low - Battery capacity is critically low; power could be lost immediately.
z Local communication lost in a power event - Communication with device has been lost during a
power event.
Communication between the Agent and the UPS using the USB or serial cable has been lost during a
power failure.
z UPS is faulty - UPS has malfunctioned, and is not working normally.
z Communication cannot establish - Communication failed to establish during startup.
The Agent cannot establish communication with the UPS via USB or serial port, or the established
communication has been interrupted.
z Local communication lost - Local communication with the UPS has been lost.
Local communication means the USB or serial connection between the Agent computer and UPS.
z Batteries are not present - Batteries are not present, the UPS cannot provide battery power in this
condition.
z Bypass is overloaded - Output is overloaded while in bypass mode.
z Output is overloaded - Output is overloaded, power may no longer be supplied soon.
The power consumption of the connected equipment exceeds the maximum load rating of the UPS. The
UPS may not continue to provide power if the overload condition is sustained.
z Available runtime is insufficient - There is not sufficient runtime for a complete shutdown even if
battery has fully recharged.
This event will occur if the UPS has insufficient runtime for the Agent computer and all Client computers
to shut down completely even the batteries have fully charged. An excessive load or long shutdown time
may cause this event. Reduce some UPS load or set a more accurate shutdown time to avoid this event
occurrence.
z Enters bypass mode - Entering bypass mode, battery power protection will no longer be provided.
z Utility power failure - Utility power failure, battery power will be supplied.
z Remaining runtime will be exhausted - Remaining runtime will be exhausted and is not sufficient for a
complete shutdown.